3DDX Side Opening Kit Keys - 3.2/3.5
3D DIAGNOSTIX, INC. · Model Surgical drill chuck key - 3.2/3.5 · UDI-DI 00850073333044
Description
A hand-held device designed to close and tighten the adjustable jaws of a surgical drill chuck onto a cutting tool, normally a drill bit or other rotational cutting tool, for a firm grip. It is inserted into any one of three side holes that are spaced around the inner barrel of the chuck, and will engage the geared portion of the outer barrel. When rotated, the key will turn the outer barrel, which in turn closes and locks the jaws of the chuck upon the cutting tool. To loosen, the reverse action is taken. It is typically made of high-grade stainless steel to resist the corrosive effects of sterilization processes. This is a reusable device.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-01-06 | Straumann USA LLC | The mix up of the impression caps provided in the package. The provided impression caps are magenta instead of brown. |
| 2025-07-24 | Dentsply IH, Inc. | The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr |
| 2025-07-24 | Dentsply IH, Inc. | The defect in the thread area will not allow the device to fully engage with an implant or analog (implant replica used for prosthetic modeling). The threads will only engage appr |
| 2025-04-14 | Prismatik Dentalcraft, Inc. | Due to packaging mix up. Package of finished devices were reported to have an incorrect finished device package inside. |
| 2025-03-08 | Straumann USA LLC | The devices are missing the laser marked depth markings. |
| 2024-06-25 | Preat Corp | Due to a manufacturing issue, the product has a out of specification rotation of the digital analog used to visually inspect dental abutments and restorations. |
| 2024-01-24 | Thommen Medical AG | The depth of the internal canal was not manufactured according to specifications. Thus, the impression coping cannot be firmly connected to the implant. |
| 2023-12-27 | TruAbutment Inc. | Retroactive: Due to defect and quality issues dental scanner may not scan properly/accurately |
| 2021-07-26 | Paltop Advanced Dental Solutions Ltd | Some devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng |
| 2021-07-26 | Paltop Advanced Dental Solutions Ltd | Some devices are outside tolerances and showed a maximal deviation of 2 degrees in the orientation between the peek head and titanium base, and an incongruence between the size eng |