RP Natural Profile Abutment 6.0mm x 4.0mm
STERNGOLD DENTAL LLC · Model 904247 · UDI-DI 00841549110672
Description
The RP Natural Profile Abutment enables the clinician to restore cases that are periodontally and aesthetically demanding. This versatile system permits the development of an emergence profile which is in harmony with the soft tissue. Final margination can be prepared to accurately follow the gingival contours in order to achieve maximum aesthetics. Intended for use with dental implants to support and/or retain removable dental prostheses in the treatment of partially or totally edentulous patients to restore chewing function. The abutment screws directly into endosseous implants or they screw into Abutment Bases which are screwed into endosseous implants.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-07-13 | Straumann USA LLC | There may be a mismatch between the implant contained inside the packaging and the information described on the outer carton label. If the the incorrect implant is installed, the i |
| 2026-03-27 | Straumann USA LLC | Includes an incorrect screw seat interface. |
| 2026-03-27 | Straumann USA LLC | Includes an incorrect screw seat interface. |
| 2026-03-17 | Straumann USA LLC | A material mix-up had occurred during the manufacturing of Straumann Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorre |
| 2026-03-17 | Straumann USA LLC | A material mix-up had occurred during the manufacturing of Straumann Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorre |
| 2025-09-30 | Prismatik Dentalcraft, Inc. | Incorrect titanium screw, packaged with dental implant. |
| 2025-06-25 | Preat Corp | Engaging titanium base was manufactured 180 degrees around the post from where it should be located in relation to the connection geometry; if the flat is on the wrong side of the |
| 2025-06-24 | Preat Corp | Due to manufacturing error, digital analog rotational feature is 180 degrees off. |
| 2025-04-17 | Straumann USA LLC | Incorrect blister labelling. |
| 2025-04-02 | Preat Corp | Due to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a shorter engagement length into the ass |