The SternSnap Attachment is indicated for use with dental implants to support and/or retain removable dental prostheses in the treatment of partially or totally edentulous patients to restore chewing function. The Stern Snap® attachment consists of a modified ball, which screws into an Abutment Base (alternatively the one-piece Stern Snap® Abutments may be screwed directly into an implant) and a retention cap, which is processed into the denture. The retention cap engages the outside of the ball shape and allows retention of the prosthesis to the denture.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-07-13 | Straumann USA LLC | There may be a mismatch between the implant contained inside the packaging and the information described on the outer carton label. If the the incorrect implant is installed, the i |
| 2026-03-27 | Straumann USA LLC | Includes an incorrect screw seat interface. |
| 2026-03-27 | Straumann USA LLC | Includes an incorrect screw seat interface. |
| 2026-03-17 | Straumann USA LLC | A material mix-up had occurred during the manufacturing of Straumann Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorre |
| 2026-03-17 | Straumann USA LLC | A material mix-up had occurred during the manufacturing of Straumann Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorre |
| 2025-09-30 | Prismatik Dentalcraft, Inc. | Incorrect titanium screw, packaged with dental implant. |
| 2025-06-25 | Preat Corp | Engaging titanium base was manufactured 180 degrees around the post from where it should be located in relation to the connection geometry; if the flat is on the wrong side of the |
| 2025-06-24 | Preat Corp | Due to manufacturing error, digital analog rotational feature is 180 degrees off. |
| 2025-04-17 | Straumann USA LLC | Incorrect blister labelling. |
| 2025-04-02 | Preat Corp | Due to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a shorter engagement length into the ass |