Description

This part contains: 1 female 1.3mm post diameter, 9mm long. These attachments are placed in the retained tooth root, which has been prepared to receive the fixed attachment component. The other component of the attachment becomes part of a patient removable overdenture, which is a denture partially supported by one or more retained roots. ERA Direct Placement Overdenture is available in standard and micro sizes. This product consist of a stainless steel female with a titanium nitride coating and a choice of four different post angles – 0° (straight), 5°, 11° and 17°, and two post diameters – 1.3mm and 1.7mm, both 9mm long. Six color coded males to create a consistent level of retention (white, orange, blue, grey, yellow, red). An optional metal jacket is also available to hold the attachment male in the denture base and is sold pre-loaded with a black fabrication male. Intended to support and/or retain removable dental prostheses in the treatment of partially or totally edentulous patients to restore chewing function.

Recalls

DateFirmReason
2026-07-13Straumann USA LLCThere may be a mismatch between the implant contained inside the packaging and the information described on the outer carton label. If the the incorrect implant is installed, the i
2026-03-27Straumann USA LLCIncludes an incorrect screw seat interface.
2026-03-27Straumann USA LLCIncludes an incorrect screw seat interface.
2026-03-17Straumann USA LLCA material mix-up had occurred during the manufacturing of Straumann Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorre
2026-03-17Straumann USA LLCA material mix-up had occurred during the manufacturing of Straumann Custom Abutments. More specifically, a raw material bar of TAN-material (SAP #701924 / Lot 7130439) was incorre
2025-09-30Prismatik Dentalcraft, Inc.Incorrect titanium screw, packaged with dental implant.
2025-06-25Preat CorpEngaging titanium base was manufactured 180 degrees around the post from where it should be located in relation to the connection geometry; if the flat is on the wrong side of the
2025-06-24Preat CorpDue to manufacturing error, digital analog rotational feature is 180 degrees off.
2025-04-17Straumann USA LLCIncorrect blister labelling.
2025-04-02Preat CorpDue to manufacturing issues, abutment products were manufactured with screw seat located too high, which may cause the mating screw to have a shorter engagement length into the ass