Description

The Met One Technologies Kodiak Lumbar Spacer System is a lumbar intervertebral body fusion device that is implanted into the vertebral body space to improve stability of the spine while supporting fusion. The Kodiak Lumbar Spacer System may be implanted bilaterally using a posterior (PLIF) approach, or as a single device employing a transformational (TLIF) approach. The implants have a central endplate window to permit packing of autograft and/or allograft bone, teeth on the superior and inferior surfaces, and lateral windows for radiographic visualization. The implants are additively manufactured from Ti-6Al-4V ELI and are available in a variety of heights, footprints, and lordotic configurations to suit individual patient anatomy.

Recalls

DateFirmReason
2025-11-03Orthofix U.S. LLCLabeling contains claims that are not consistently present.
2025-11-03Orthofix U.S. LLCLabeling contains claims that are not consistently present.
2025-10-29Medicrea InternationalDue to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant.
2025-10-29Medicrea InternationalDue to complaints, orthopedic rotation tool handle may untread from the shaft resulting in the inability to rotate implant.
2025-09-16Medtronic Sofamor Danek USA IncExpandable interbody system cage may loose height or collapse (loss of lordosis), which could result in migration, subsidence and/or neurological injury. Therefore, surgical techni
2025-08-06SEASPINE ORTHOPEDICS CORPORATIONInserter, used as part of a system with an intervertebral body fusion device, may contribute to difficulty disengaging the implant or improper implant positioning, which may may le
2025-06-24Orthofix U.S. LLCA 37 mm implant width intervertebral body fusion device has a labeling discrepancy with incorrect width of 33 mm stated on the outer label side flap and inner label side flap infor
2025-02-20Orthofix U.S. LLCThe product is mislabeled with the incorrect anterior height of 10mm, but the laser marking on the implant and corresponding trial both show the correct anterior height of 10.5mm.
2024-12-15Alphatec Spine, Inc.Complaints have been received regarding post-operative implant collapse.
2024-08-14Innovasis, IncDue to interfacing issues between the implant trial and inserter of the lumbar intervertebral fusion device.