N/A
HARDY DIAGNOSTICS · Model L27 · UDI-DI 00819398022170
Description
DTM (Dermatophyte Test Media) Agar Slant, 7.5ml Slant, order by the package of 20 (Dermatophyte Test Medium) For the isolation and identification of dermatophytic fungi such as Microsporum canis, the causative agent of ringworm. It is also designed to detect dermatophytes such as Epidermophyton and Trichophyton spp. The addition of Gentamicin and Chlortetracycline act as broad spectrum antimicrobics to inhibit a wide range of interfering gram-positive and gram-negative bacteria. Cycloheximide is added to inhibit saprophytic non-pathogenic fungi. Phenol red, the pH indicator, is affected by the presence of dermatophytes (Epidermophyton, Microsporum, and Trichophyton spp.), which all produce alkaline metabolites. Vials are made of shatter resistant polycarbonate plastic with a wide mouth opening for easy inoculatio
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-07-11 | Remel, Inc | The products may contain surface and subsurface contamination of Listeria monocytogenes. |
| 2025-07-11 | Remel, Inc | The products may contain surface and subsurface contamination of Listeria monocytogenes. |
| 2025-07-11 | Remel, Inc | The products may contain surface and subsurface contamination of Listeria monocytogenes. |
| 2025-04-24 | Mckesson Medical-Surgical Inc. Corporate Office | transit delays of certain cold chain products due to severe thunderstorms which may caused the products to be stored outside the recommended labeled storage conditions. This failur |
| 2025-02-13 | Remel, Inc | Product may contain surface and subsurface contamination of Listeria monocytogenes which is typically visible immediately upon removal from the packaging, appearing on the blood si |
| 2025-02-13 | Remel, Inc | Product may contain surface and subsurface contamination of Listeria monocytogenes which is typically visible immediately upon removal from the packaging, appearing on the blood si |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2022-11-09 | Biomerieux Inc | As the temperature and time out of range was exceeded, product performances cannot be guaranteed |
| 2020-12-10 | Remel Inc | The blood agar side of the bi-plate may not grow some patient isolates or QC organisms as intended. |
| 2018-08-02 | Acumedia Manufacturers, Inc. | Expiration date on the label is incorrect. Correct expiration date was November 30, 2020 and label on distributed product listed the expiration date as November 30, 2021. |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.