Home › STRYKER CORPORATION › PhotonBlade
PhotonBlade
STRYKER CORPORATION · Model PB1 · UDI-DI 00816728020158
GEI
Prescription
10
510(k) clearances
118,289
Adverse events (469 deaths)
644
Recalls
858
Facilities
Description
The PhotonBlade is an RF device coupled with illumination that is indicated for cutting and coagulation of soft tissue during surgical procedures. It is intended to be used with a variety of standard commercially available electrosurgical units.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-18 | Olympus Corporation of the Americas | Potential labeling deficiency in which an outer shelf box is incorrectly labeled as a 37-cm device. |
| 2026-06-08 | Stryker Corporation | There has been an increased amount in reported complaints consistently describing leaking from the handpiece during use. |
| 2026-06-08 | Stryker Corporation | There has been an increased amount in reported complaints consistently describing leaking from the handpiece during use. |
| 2026-06-02 | Maquet Cardiovascular, LLC | Getinge identified that Vasoview Hemopro 2 devices from Lot 3000547797 were exposed to an out-of-specification sterilization dose during a gamma sterilization run (Run ID 1183-2878 |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-03-23 | Olympus Corporation of the Americas | Potential for detachment of a distal tip component of the device during use. |
| 2026-02-25 | Olympus Corporation of the Americas | Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting For |
| 2026-02-25 | Olympus Corporation of the Americas | Olympus identified that the Cutting Forceps contain components for which the supplier did not adequately validate the welding process. Defective welds can result in the Cutting For |