Impact
NVision Biomedical Technologies, Inc. · Model PP-1000T-301 · UDI-DI 00810135963336
Description
PEEK Nail 3.0 Drill Guide The Impact PEEK Union Nail System is indicated for maintenance of alignment and fixation of bone fractures, osteotomies, arthrodeses or bone grafts in the presence of appropriate additional immobilization (e.g. rigid fixation implants, cast, brace). The Impact PEEK Union Nail System contains 3.0mm - 4.5mm diameter, 50mm long pins manufactured from HA Enhanced PEEK (ASTM F2026). The implants are designed with strategically placed ridges to improve initial stability and cannulated structure to simplify insertion over a k-wire. Additionally, it was designed to include tantalum pins to ensure optimal imaging visibility for device placement accuracy.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2023-11-30 | Waldemar Link GmbH & Co. KG (Mfg Site) | Mislabeled: Angle and height of the device marked as L(large) corresponds to the small/medium dimensions due to a product mix-up. This may result in too little bone material resec |
| 2022-10-10 | Hologic, Inc | IFU was not provided with the Sizer Set sterilization tray Revised Sterilization Instructions for Sizer Set |
| 2019-08-21 | Zimmer Biomet, Inc. | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. |
| 2019-08-21 | Zimmer Biomet, Inc. | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. |
| 2019-08-21 | Zimmer Biomet, Inc. | Elevated levels of bacterial endotoxin and residual debris remain on the devices due to cleaning issue. |
| 2018-03-26 | Zimmer Biomet, Inc. | Potential failure of sterile packaging seal. |
| 2017-08-07 | Synthes, Inc. | May have difficulty attaching the drill sleeve to the plate. If the drill sleeve will not connect to the plate intraoperatively, surgical delay could occur. If the pilot hole is dr |
| 2017-04-25 | Cook Inc. | reprocessing instructions do not provide sufficient detailed information for the cleaning, disinfection, and sterilization of these products |
| 2016-08-09 | Zimmer Biomet, Inc. | Old revisions and new revisions of the soft tissue sleeve and recon targeting arm are not interchangeable, as the new revision tissue sleeve will not fit into the old revision targ |
| 2016-06-07 | Synthes (USA) Products LLC | DePuy Synthes is initiating a voluntary medical device recall due to Blade/Screw Guide Sleeves (Part # 03.037.017) may have been manufactured with a slightly larger than specified |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docs