ONE-CARE PRO Safety Lancets, Button-Activated, 21G x 1.8mm
MediVena, LLC · Model ONE-CARE PRO Safety Lancets, Button-Activated, 21G x 1.8mm · UDI-DI 00810008210673
Description
MediVena ONE-CARE PRO Push Button Activated Safety Lancets are disposable, single-use, preloaded devices with needlestick prevention mechanism for blood micro-sampling. The product has T-shape main housing and concaved button for stable grip within the hand and easy activation. ONE-CARE PRO Safety Lancets feature long safety tab for convenient twist off and pull out, optimized skin contact area of round shape for convenient placement on the test site. Dual-spring mechanism allows for quick and reliable needle retraction to protect against accidental needlestick injuries. STEP 1 Twist off the safety cap by a full turn of 360 degree, then pull it out, STEP 2 Press the top push button to activate the device, STEP 3 Collect blood sample and dispose the safety lancet into sharps container.
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2021-03-16 | Cardinal Health Inc. | Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results. |
| 2021-03-16 | Cardinal Health Inc. | Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results. |
| 2021-03-16 | Cardinal Health Inc. | Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results. |
| 2021-03-16 | Cardinal Health Inc. | Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results. |
| 2013-08-19 | Roche Diagnostics Operations, Inc. | Internal Roche inspections have revealed that after the lancet is used for a finger stick, the needle may not fully retract back within the lancet drum or back into the cap. This a |
| 2013-07-10 | Becton Dickinson & Company | The Lancet will not retract after activation thus creating a potential for exposure to a used sharp. |
| 2013-07-03 | KooJoo Trading Company | Lancets were not sterilized within the dose range established by sterilization validation. |
| 2009-05-13 | Roche Diagnostics Corp. | The lancet cap may be missing, which could result in an unintended lancet stick to the user. |
| 2008-08-27 | Sarstedt Inc | The product from this lot may not retract the lancet into the safe position inside the lancet body after the trigger is actuated. |
| 2008-07-18 | Facet Technologies | The Alternate Site Cap was not included in the package as indicated on the labeling. |