MediVena, LLC · Model 1005 ONE-CARE PLUS Safety Lancets 21G x 2.4mm, ExtraFlow, Green, 100/bx, 20bx/cs · UDI-DI 00810008210215

FMK
1
510(k) clearances
14,104
Adverse events (2 deaths)
17
Recalls
158
Facilities

Description

Contact-activated ONE-CARE PLUS Safety Lancets 21G x 2.4 mm are designed with an ergonomic body for a comfortable grip, ensuring ease of use during procedures. The reliable safety activation mechanism guarantees consistent performance, while the wide cap allows for easy twist-off, facilitating straightforward preparation for use. This innovative design provides an optimal combination of safety, comfort, and convenience.

Recalls

DateFirmReason
2021-03-16Cardinal Health Inc.Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results.
2021-03-16Cardinal Health Inc.Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results.
2021-03-16Cardinal Health Inc.Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results.
2021-03-16Cardinal Health Inc.Due to shipping delays the devices were exposed to temperature excursions of 31.9F, intermittently over a 2 hour and 15 minute period of time which may cause inaccurate results.
2013-08-19Roche Diagnostics Operations, Inc.Internal Roche inspections have revealed that after the lancet is used for a finger stick, the needle may not fully retract back within the lancet drum or back into the cap. This a
2013-07-10Becton Dickinson & CompanyThe Lancet will not retract after activation thus creating a potential for exposure to a used sharp.
2013-07-03KooJoo Trading CompanyLancets were not sterilized within the dose range established by sterilization validation.
2009-05-13Roche Diagnostics Corp.The lancet cap may be missing, which could result in an unintended lancet stick to the user.
2008-08-27Sarstedt IncThe product from this lot may not retract the lancet into the safe position inside the lancet body after the trigger is actuated.
2008-07-18Facet TechnologiesThe Alternate Site Cap was not included in the package as indicated on the labeling.