FDA Device Intelligence
Home › Focal Healthcare Inc › Fusion Bx

Fusion Bx

Focal Healthcare Inc · Model 1.1 · UDI-DI 00628055858003

LLZ Prescription
1
510(k) clearances
19,695
Adverse events (41 deaths)
560
Recalls
632
Facilities

Description

Fusion Bx is designed to display the 2D live video received from commercially available ultrasound machines and use this 2D video to reconstruct a 3D ultrasound image volume. The system is designed to work with clinicians’ existing ultrasound machines, transrectal ultrasound (TRUS) probes, commercially available needles, needle guides/templates and needle gun combination. Additional software features include patient data management, multi-planar reconstruction, segmentation, image measurements and 3D image registration. The device will assist clinicians in planning and performing image-guided interventional procedures such as biopsies and placing instruments in the prostate for adult men with suspected prostate cancer. Fusion Bx is comprised of a laptop-based workstation and a hardware assembly. The included hardware consists of a frame grabber, encoder converter, hardware arm (comprising of a swing arm, counterbalance, tracker and stepper), and stand. The stepper holds the ultrasound probe and measures probe position while the physician performs a normal ultrasound imaging procedure of the subject prostate. Encoders in the stepper and tracker send joint movement information to the computer workstation which tracks probe position and orientation. Control of the ultrasound probe and ultrasound system is done manually by the physician, just as it would be in the absence of Fusion Bx. However, by tracking the position and orientation of the ultrasound probe while capturing the video image, the workstation is able to reconstruct and display a 3D image and 3D rendered surface model of the prostate and to display the live image position within the prostate.

Recalls

DateFirmReason
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-31GE HealthcareUnder certain conditions historical imaging data migrated from a legacy system may become incorrectly associated with a different patient. If this occurs, studies or images may be
2026-07-22FUJIFILM Healthcare Americas CorporationSoftware issue may cause the ruler measurement to be inaccurate.
2026-07-22Merge Healthcare, Inc.Software issue may cause measurements to be displayed inaccurately.
2026-06-30Merge Healthcare, Inc.Merge Healthcare has identified a potential issue that may cause thumbnails from a previously opened patient study to be displayed in the Thumbnail Bar while a different patient st
2026-06-30Merge Healthcare, Inc.Merge Healthcare has identified a potential issue that may cause thumbnails from a previously opened patient study to be displayed in the Thumbnail Bar while a different patient st

Query this across every FDA database — by API.

Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.

Get your free API keyRead the docs
Data compiled from public U.S. FDA sources (GUDID, 510(k)/PMA, MAUDE, recalls, establishment registration). Adverse-event reports are unverified and do not establish causation. Informational only — not medical, clinical, or regulatory advice.