FDA Device Intelligence
HomeShockwave Medical, Inc. › Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter

Shockwave IVL System with the Shockwave S4 Peripheral IVL Catheter

Shockwave Medical, Inc. · Model S4IVLK3540 · UDI-DI 00195451000331

OEZPPNJAA Prescription
0
510(k) clearances
1,221
Adverse events (17 deaths)
223
Recalls
59
Facilities

Description

The Shockwave S4 Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The distal catheter and balloon are hydrophilic coated to increase lubricity. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).

Recalls

DateFirmReason
2026-07-20Medline Industries, LPDownstream recall - manufacturer recalled specific lots of BD ChloraPrep Clear - 1mL Applicators. Affected product may exhibit an open or incomplete seal on the packaging of the ap
2026-07-14Cardinal Health 200, LLCCardinal Health was recently informed of a medical device recall from MEDICOM concerning the Ritmed Neurological Sponges. The recall is being issued due to unexpected variability o
2026-07-10Medline Industries, LPKits contain a potentially contaminated component which were recalled by the manufacturer
2026-06-29American Contract Systems IncThe Convenience Kits contain Medline s Red Rubber Intermittent Catheters (8Fr-22 Fr) and Red Rubber Intermittent Catheter Trays. Medline Industries, LP has identified representativ
2026-06-29American Contract Systems IncThe Convenience Kits contain Medline's Red Rubber Intermittent Catheters (8Fr-22 Fr) and Red Rubber Intermittent Catheter Trays. Medline Industries, LP has identified representativ
2026-06-29American Contract Systems IncThe Convenience Kits contain Medline s Red Rubber Intermittent Catheters (8Fr-22 Fr) and Red Rubber Intermittent Catheter Trays. Medline Industries, LP has identified representativ
2026-06-29American Contract Systems IncThe Convenience Kits contain Medline s Red Rubber Intermittent Catheters (8Fr-22 Fr) and Red Rubber Intermittent Catheter Trays. Medline Industries, LP has identified representativ
2026-06-12Medline Industries, LPThe kits contain BD ChloraPrep Clear - 1 mL and FREPP Clear 1.5 mL Applicators which have a potential breach of sterility in the packaging, due to wrinkles in the paper lidding whi
2026-06-11Medline Industries, LPMedline Industries, LP is issuing a recall for specific Medline convenience kits containing BD PurPrep 26 mL which may be contaminated with low levels of Bacillus species.
2026-06-01Argon Medical Devices, IncKits containing Lidocaine HCL Injection USP 1% 10mg/mL 5mL ampules subject to another recall recalled due to not meeting release criteria for sterility.

Query this across every FDA database — by API.

Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.

Get your free API keyRead the docs