Shockwave IVL System with the Shockwave M5+ Peripheral IVL Catheter
Shockwave Medical, Inc. · Model M5PIVL6560 · UDI-DI 00195451000263
Description
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-08-11 | Medline Industries, LP | The kits contain certain lots of sterile applicators which may contain fungal contamination that may occur under certain environmental conditions, allowing the growth of Aspergillu |
| 2026-08-10 | AVID Medical, Inc. | Product may be potentially contaminated with a lubricant used during the manufacturing process. |
| 2026-08-10 | American Contract Systems Inc | Kits contain manufacturer-recalled perineal care (pericare) wipes within urinary catheter trays, which may be contaminated with a lubricant used during the manufacturing process. U |
| 2026-08-10 | AVID Medical, Inc. | Product may be potentially contaminated with a lubricant used during the manufacturing process. |
| 2026-08-10 | AVID Medical, Inc. | Product may be potentially contaminated with a lubricant used during the manufacturing process. |
| 2026-08-10 | AVID Medical, Inc. | Product may be potentially contaminated with a lubricant used during the manufacturing process. |
| 2026-07-29 | Cardinal Health 200, LLC | The Urinary Catheter Trays contain CliniClean Pericare Wipes which may potentially be contaminated with a lubricant used during the manufacturing process. If a contaminated wipe is |
| 2026-07-20 | Medline Industries, LP | Downstream recall - manufacturer recalled specific lots of BD ChloraPrep Clear - 1mL Applicators. Affected product may exhibit an open or incomplete seal on the packaging of the ap |
| 2026-07-14 | Cardinal Health 200, LLC | Cardinal Health was recently informed of a medical device recall from MEDICOM concerning the Ritmed Neurological Sponges. The recall is being issued due to unexpected variability o |
| 2026-07-10 | Medline Industries, LP | Kits contain a potentially contaminated component which were recalled by the manufacturer |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docs