Shockwave IVL System with the Shockwave M5+ Peripheral IVL Catheter
Shockwave Medical, Inc. · Model M5PIVL3560 · UDI-DI 00195451000201
Description
The Shockwave M5+ Intravascular Lithotripsy (IVL) Catheter consists of an array of miniaturized lithotripsy emitters, located inside a balloon, that generate acoustic pressure waves within the target treatment site, disrupting calcium within the lesion and allowing subsequent dilation of a peripheral artery stenosis using low balloon pressure. Two radiopaque marker bands inside the balloon aid in positioning. The proximal hub has three ports: one for inflation/deflation of the balloon with 50/50 saline/contrast medium, one for the ‘Over-the-wire’ (OTW) guidewire lumen, and one for connection to the IVL Connector Cable (and IVL Generator).
Recalls
| Date | Firm | Reason |
|---|---|---|
| 2025-10-27 | Philips North America | Between July 2024 and June 2025, Philips Azurion R3.0 systems with a FlexArm stand were shipped without the Source-to-Skin Distance (SSD) Spacer. The SSD spacer is necessary to me |
| 2025-10-01 | Philips Medical Systems DMC GmbH | Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/p |
| 2025-10-01 | Philips Medical Systems DMC GmbH | Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/p |
| 2025-10-01 | Philips Medical Systems DMC GmbH | Philips has identified that some ceiling suspension telescopic carriages manufactured from July 2024 through June 2025 may be difficult to move vertically (i.e. additional force/p |
| 2025-06-04 | Siemens Medical Solutions USA, Inc | A resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire. |
| 2025-06-04 | Siemens Medical Solutions USA, Inc | A resistor in the frequency inverter may strongly overheat potentially igniting the plastic housing of the frequency inverter on fire. |
| 2024-09-06 | SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION | X-ray R/F system software with certain versions of the control board may occasionally fail to display images when switching from Fluoroscopy mode to Radiography mode, which may lea |
| 2024-09-06 | SHIMADZU CORPORATION MEDICAL SYSTEMS DIVISION | X-ray R/F system software with certain versions of the control board may occasionally fail to display images when switching from Fluoroscopy mode to Radiography mode, which may lea |
| 2024-07-29 | Agfa N.V. | Potential for the front lever chain of the DR 800 table to fail. |
| 2023-12-15 | Philips North America | Issue 1: Mixed Images: The Radio Fluoroscopy (RF) viewer may also display a previous patient s radiography (RAD) images when starting the next patient scan while the previous patie |