Home › Device types › IKX
Aid, Transfer
FDA product code IKX · Class 1 · Physical Medicine
1,259
Registered devices
2,515
Adverse events
20
Recalls
18
510(k) clearances
Devices with this code
Molift — Etac A/SImmedia — Etac Immedia A/SBinder Lift — We Stitch Stuff, LLCInvisia™ BathBench ADA (Oil Rubbed Bronze, Honey Stain) — Healthcraft Products Inc.Easy Mount™ 9 Hole Flange w/Cover (32 "KNURLED STEEL) — Healthcraft Products Inc.Invisia™ Shower Bench, 24"/610mm (Matte White, Walnut Stain) — Healthcraft Products Inc.Invisia™ SerenaSeat™ Pro (Polished Chrome, 26"/66cm, Medium) — Healthcraft Products Inc.Banana — GBUK LTDImmedia — Etac Immedia A/SEasy Mount™ 9 Hole Flange w/Cover (24" White) — Healthcraft Products Inc.Invisia™ SerenaSeat™ (Matte Grey, 26"/66cm, Honey Stain) — Healthcraft Products Inc.Molift — Etac A/SMolift — Etac A/SMolift — Etac A/SArjo Slides Sheet — Arjohuntleigh ABVive — VIVE HEALTH LLCMolift — Etac A/SSuperslide — Therafin CorporationSuperslide — Therafin CorporationBinder Lift — We Stitch Stuff, LLCCONDOR — GRAINGER INTERNATIONAL, INC.E.M Adams co, inc. — E.M. ADAMS, INC.Invisia™ SerenaSeat™ Pro — Healthcraft Products Inc.Banana — GBUK LTD
Recent recalls
| Date | Firm | Reason |
|---|---|---|
| 2024-11-05 | NOA Medical Industries Inc | Red button used to engage side rails can break or become stuck making it difficult to engage the side rail. |
| 2020-09-15 | Medline Industries Inc | The buckle on the Gait Belt may break due to degradation of the material due to exposure to gamma radiation. |
| 2017-08-10 | Medline Industries Inc | The locking mechanism on the belt may fail to secure/hold the strap when in locked position potentially allowing the belt strap to slip through the buckle. |
| 2017-08-10 | Medline Industries Inc | The locking mechanism on the belt may fail to secure/hold the strap when in locked position potentially allowing the belt strap to slip through the buckle. |
| 2017-05-30 | EOS Imaging | ROTH MOBELI grab handles could detach and patient could fall if the EOS system operator does not follow instructions. Before each use, the operator must examine |
| 2015-03-26 | Handicare USA, Inc. | Complaints were received that the heat-welded seam on the wipeable belt's strap tore when force was applied. |
| 2014-04-15 | Handicare USA, Inc. | During the period of April 2009 May 2011, Handicare AB used a wing handle in which the screw and handle, after repeated tightening, may slide apart. This cause |
| 2012-03-20 | North Coast Medical Inc | Due to a consumer complaint, North Coast Medical determined that due to a design flaw, there was not enough plastic support material to retain bracket bolts whe |
| 2009-07-09 | Nutech Manufacturing Corp | Safety chair used in shower/bath may not meet specifications for weight load. |
| 2009-07-09 | Nutech Manufacturing Corp | Safety chair used in shower/bath may not meet specifications for weight load. |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docsSourced from public U.S. FDA data. Informational only — not medical or regulatory advice. Not affiliated with the FDA.