Home › Device types › HSB
Rod, Fixation, Intramedullary And Accessories
FDA product code HSB · Class 2 · Orthopedic
0
Registered devices
37,998
Adverse events
690
Recalls
532
510(k) clearances
Devices with this code
TFN-ADVANCE — Synthes GmbHStainless Steel Femoral Nailing System — ORTHOFIX SRLPRECICE® Bone Transport System — NUVASIVE SPECIALIZED ORTHOPEDICS, INC.AFFIXUS®CORTICAL BONE SCREW — Biomet Orthopedics, LLCMETA PLATE - LARGE — Biomet Orthopedics, LLCCORTICAL SCREW 3.5mm x 55.0mm — ADVANCED ORTHOPAEDIC SOLUTIONS, INC.AUTOBAHN — GLOBUS MEDICAL, INC.Piccolo Composite Nailing System — CARBOFIX ORTHOPEDICS LTDPediatric Nailing Platform | Femur — ORTHOPEDIATRICS CORP.PNP Femur — ORTHOPEDIATRICS CORP.GAMMA — Stryker GmbHTalon™ DistalFix™ Proximal Femoral Nail — Orthopedic Designs North America, Inc.Phantom Hindfoot TTC/TC Nail System — Paragon 28, Inc.Pediatric Nailing Platform Femur — ORTHOPEDIATRICS CORP.AOS CAPTURED CANCELLOUS SCREW, FULLY THREADED 6.5mm x 50mm — ADVANCED ORTHOPAEDIC SOLUTIONS, INC.GAP ENDO-EXO MEDULLARY SYSTEM — Orthopediatrics Canada ULCGAMMA — Stryker GmbHT2 ALPHA — Stryker GmbHMeta Nail — Smith & Nephew, Inc.BONE SCREW, CORTICAL — Biomet Orthopedics, LLCNatural Nail® — Zimmer, Inc.IM NAIL PLATFORMCANCELLOUS SCREW — Biomet Orthopedics, LLCORTHOFIX — ORTHOFIX SRLORTHOFIX — ORTHOFIX SRL
Recent recalls
| Date | Firm | Reason |
|---|---|---|
| 2026-03-16 | Smith & Nephew, Inc. | Humeral nail due to a manufacturing error is missing distal holes and if implanted may lead to revision surgery but, if the missing holes are identified before |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
| 2025-12-02 | Zimmer, Inc. | Affected implants may have undersized distal diameter along length of the shaft, which could lead to implant fatigue fracture. Potential health risk if implant |
Query this across every FDA database — by API.
Linked GUDID · 510(k)/PMA · MAUDE · recalls · establishments. Free tier, no card required.
Get your free API keyRead the docsSourced from public U.S. FDA data. Informational only — not medical or regulatory advice. Not affiliated with the FDA.
